Connecting of feeding cable, Connection to normal socket, Direct connection to electric supply – Инструкция по эксплуатации KORTING OGG741RI
Страница 21
21
Connecting of feeding cable
If apparatus is not fi tted with feeding cable,
use cable Mod. H05RR-F or H05RN-F stating
suitable section of the cable which has to be
connected to terminal. To obtain that you have
to:
Connect the supply cable to the terminal strip
of the oven (fi g. 3), keeping the earth wire 3
cm. longer
than the active conductors (live/neutral).
Connect cable’s wires as follows:
L = (live) brown or red wire
N = (neutral) blue wire
╧ =(earth) yellow - green wire.
N.B. Feeding’s cable temperature should
never reach 100°C.
Connection to normal socket
Connect feeding cable a normal plug suit-
able to the load stated on data plate. When the
cooker has been built-in household check that
the plug is accesible.
Direct connection
to electric supply
If an appliance is not equipped with supply
cable and plug, the power supply must be fi tted
with a disconnect switch in which the distance
between contacts permits total disconnection
in accordance with overvoltage category III, as
required by installation regulations. The yellow/
green earth wire should not be controlled by
the switch.
Supply 220 / 230 V~
Oven type
section
Type of cable
Gas oven
3x0,75 mm
2
Rubber H05 RR-F
or Rubber H05
RN-F
Gas oven +
electric grill
3 x 1,5 mm
2
ATTENTION: If the supply cable is damaged,
it must be replaced by the manufacturer or by
his after-sales service, or by a similar qualifi ed
person, in order to prevent any risk.