Connecting of feeding cable

If apparatus is not fi tted with feeding cable,

use cable Mod. H05RR-F or H05RN-F stating
suitable section of the cable which has to be
connected to terminal. To obtain that you have
to:

Connect the supply cable to the terminal strip

of the oven (fi g. 3), keeping the earth wire 3
cm. longer
than the active conductors (live/neutral).

Connect cable’s wires as follows:

L = (live) brown or red wire
N = (neutral) blue wire
╧ =(earth) yellow - green wire.
N.B. Feeding’s cable temperature should

never reach 100°C.

Connection to normal socket

Connect feeding cable a normal plug suit-

able to the load stated on data plate. When the
cooker has been built-in household check that
the plug is accesible.

Direct connection

to electric supply

If an appliance is not equipped with supply

cable and plug, the power supply must be fi tted
with a disconnect switch in which the distance
between contacts permits total disconnection
in accordance with overvoltage category III, as
required by installation regulations. The yellow/
green earth wire should not be controlled by
the switch.

Supply 220 / 230 V~

Oven type

section

Type of cable

Gas oven

3x0,75 mm

2

Rubber H05 RR-F

or Rubber H05

RN-F

Gas oven +

electric grill

3 x 1,5 mm

2

ATTENTION: If the supply cable is damaged,

it must be replaced by the manufacturer or by
his after-sales service, or by a similar qualifi ed
person, in order to prevent any risk.