Инструкция по эксплуатации VEGA VEGAFLEX 83 Foundation Fieldbus PFA insulated

Страница 89

Advertising
background image

89

11 Приложение

VEGAFLEX 83 • Foundation Fieldbus

44227-R

U-130930

FF desciptor

Description

Unit

FILL_HEIGHT_VALUE

Filling height. The unit is defined in "FILL_HEIGHT_VALUE_

UNIT"

FILL_HEIGHT_VALUE_UNIT Filling height unit
CONST_VALUE

Constant value

SECONDARY_VALUE_1_

TYPE

Secondary value 1 type

SECONDARY_VALUE_2_

TYPE

Secondary value 2 type

FILL_HEIGHT_VALUE_Type

Filling height value type

DIAGNOSIS

AITB Diagnosis

DIAG_MASK_1
DIAG_OUT_1
DIAG_MASK_2
DIAG_OUT_2
DEVICE_IDENTIFICATION

Manufacturer ID, device type, bus type ID, measurement

principle, serial number, DTM ID, device revision

DEVICE_NAME

Device name

IS-SPARE_ELECTRONICS

Device name

DEVICE_VERSION_INFO

Hard- and software version for system, function and error

CALIBRATION_DATE

Day, month and year

FIRMWARE_VERSION_ASCII Software version
HW_VERSION_ASCII

Hardware version

ADJUSTMENT_DATA

Min./max.-adjustment physical, percent and offset

FIRMWARE_VERSION_MAIN Firmware versions major, minor, revision and build
PHYSICAL_VALUES

Distance, distance unit, distance status, level and status

DEVICE_UNITS

Distance and temperature units of the instrument

APPLICATION_CONFIG

Medium type, media, application type, vessel bottom, vessel

height

LINEARIZATION_TYPE_SEL Type of linearization
SIMULATION_PHYSCAL
INTEGRATION_DATA

Physical offset and integration time

DEVICE_CONFIG_PULS_

RADAR

Electronics variant, probe type, max. measuring range, antenna

extension length, adjustment propagation antenna extension

lprapproval configuration

ADJUSTMENT_LIMITS_MIN Min. range min.-/max.- values physical, percent, offset
ADJUSTMENT_LIMITS_MAX Max. range min.-/max.- values physical, percent, offset

%

FALSE_SIGNAL_COMMAND

%

FALSE_SIGNAL_CMD_

CREATE_EXTEND
FALSE_SIGNAL_CMD_

DELET_REGION

Advertising