Инструкция по эксплуатации Beko CG 61110 G
Страница 28
Внимание! Текст в этом документе был распознан автоматически. Для просмотра оригинальной страницы Вы можете воспользоваться режимом "Оригинал".
/n
models with " covered fype-fermlnal block
If there is no supply cord attached to your
oven, it is necessary to select the type
indicated on below and follow the instructions
Disconnect the appliance from the network.
i.open terminal
cover with
screwdriwer
2.open cable clamp
3. Change the cable
according to this schema
Take care to connect as
below:
Brown cable
=
L (Live)
Blue cable = N
Use your oven with H03 RR-F 3x 0.75
mm2 supply cord, and 10 A fuse.
In models with block type terminal.
The connection between the supply
cord and the oven should be installed
by a qualified electrician. The
green/yellow and point of the supply
cord shold be connected to the
entrance.
■i
Do not forget to have your oven
earthed by a qualified electrician.
Our company shall not be held
responsible for any damage caused
by the utilization of the oven without
ground cabling and wrong
connection.
L N 4.
Green/Yellow cable = E
(Earth)
i
4. Fix the cable clamp
5. Close terminal cover
Adjacent side walls above the
appliance must not be nearer than
150 mm to the cooker and should be
of heat resistant material. Leave at
least 750 mm clearance above the
hotplates.
The appliance should be located on
a level surface.
The two front feet can be adjusted as
required. To ensure that your appliance
is standing level adjust the two front
feet by turning clockwise or
counterclockwise until the product is
in firm contact with the floor.