SPECIFICATIONS

Power supply

220-240V 50-60 Hz

Fan Speed Adjustment

MAX

MED

SLEEP

CLEAN AIR

Fan Speed (m

3

/hour)

180

125

52

Rated Power (W)

27

12

4.1

Noise Level (dBA)

48

38

21

CLEAN AIR

&HUMIDIFY

Fan Speed (m

3

/hour)

180

125

52

Rated Power (W)

27

12

4.1

Noise Level (dBA)

48

38

21

Humidification (mL/hour)*1

350

280

140

Recommended Room Size (m

2

)*2

~21

High density Plasmacluster ion recommended room size (m

2

)*3

~17

Humidifying Tray Capacity (L)

1.8

Sensors

Dust / Temperature & Humidity

Filter type

Dust collection

HEPA *4

Deodorization

Deodorizing

Cord Length (m)

2.0

Dimensions (mm)

380 (W) × 197 (D) × 570 (H)

Weight (kg)

7.2

*1 • The amount of humidification changes in accordance with indoor and outdoor temperature and

humidity.

The amount of humidification increases as temperatures rises or humidity decreases.

The amount of humidification decreases as temperatures decrease or humidity rises.

• Measurement Conditions : 20 ºC, 30 % humidity (JEM1426)

*2 • The recommended room size is appropriate for operating the unit of maximum fan speed.

• The recommended room size is an area in which a given amount of dust particles can be removed

in 30 minutes.

*3 • Room size in which approximately 7000 ions per cubic centimeter can be measured in the center of

the room when the unit is placed next to a wall, is running at maximum settings, and is at a height

of approximately 1.2 meters from the floor.

*4 • The filter removes more than 99.97% of particles at least 0.3-microns in size. (JEM1467)

Standby Power

When the unit’s power plug is inserted in a wall outlet it consumes about 0.9 watts of standby power in order to

operate electrical circuits.

To conserve energy, unplug the power cord when the unit is not in use.